To compare, in singleton and twin pregnancies, the effectiveness of transvaginal ultrasound versus digital examination in predicting preterm delivery in women with suspected preterm labor.
Title: Transvaginal Ultrasound in the Prediction of Preterm Delivery:
Singleton and Twin Gestations
Authors: M. G. CRANE, MD, FRCS(C), M. VAN DEN HOF, MD, FRCS(C), B. A. ARMSON, MD, FRCS(C), AND R. LISTON, MB, FRCS(C)
Institution: Department of Obstatrics and Gynecology. Memorial University of Nnewfoundland, St. John's, Newfoundland; and the Department of Department of Obstetrics and Gynecology, Dalhousie University, Halifax, Nova Scotia, Canada.
Study Design: This is a prospective group-comparison (modified case
control) using cross-sectional data.
Rating:
Abstract:Objective: To compare, in singleton and twin pregnancies, the effectiveness of transvaginal ultrasound versus digital examination in predicting preterm delivery in women with suspected preterm labor.
Methods: Transvaginal ultrasound and pelvic examinations were performed on patients admitted with suspected preterm labor between 23 and 33 weeks' gestation. Ultrasound assessment of cervical length and the presence of funneling with fundal pressure were recorded for each patient, and the results were compared with dilatation and effacement as assessed by digital examination for the prediction of preterm delivery in the two groups (singletons and twins).
Results: One hundred sixty-two subjects were recruited (136 singletons and 26 twin pregnancies), with no significant demographic differences between the groups. Overall, 33% of the participants delivered preterm (27% of singletons, 62% of twins). Using receiver operating characteristic curves, the best cutoff points were 30 mm for endocervical length at ultrasound, 50% for effacement, and 1.5 cm for dilatation. Of these, the best predictor was endocervical length, which was a better predictor in singleton than in twin pregnancies. Of the potential predictors, including endocervical length, funneling, dilatation, and effacement, only endocervical length was an independent predictor of preterm delivery at less than 34 weeks' gestation for both singletons and twins by multiple logistic regression. When analyzed for delivery at less than 37 weeks' gestation, this relation held true for singletons but not twins. Endocervical length less than 30 mm had a sensitivity of 81% and 75%, specificity of 65% and 30%, positive predictive value of 46% and 63%, and negative predictive value of 90%, and 43% for singleton and twin pregnancies, respectively, in predicting spontaneous birth it less than 37 weeks' gestation.
Conclusion: Between 23 and 33 weeks' gestation, transvaginal ultrasound assessment of endocervical length is superior to funneling and digital examination in predicting preterm delivery in patients who present with suspected preterm labor, and is a better predictor in singletons than in twins. (Obstet Gynecol 1997; 90:357-63. (c) 1997 by The American College of Obstatricians and Gynecologists.)
Commentary
The primary conclusion that a sonographic endovaginal measurement of 3.0 cm or less is a better predictor of preterm deliver in singleton pregnancies than other methods (sonographic observation of funneling or digital examination) is useful information. It is less useful for twin gestations. The cervical length of 3.0 cm is on the same order as that described by others for incompetent cervix (2.5 cm or less). 1, 2 Others have agreed that the normal pre-labor cervical length should be at least 4.01 to 3.0 cm. 3,4
The study population excluded patients with a diagnosis of active preterm labor, active vaginal bleeding, placenta previa, ROM, cervical cerclage, known stillbirths, cervical dilation greater than 3 cm, and multiple gestations greater than twins; i.e., they only included suspected preterm labor between 23 and 33 weeks gestation with regular contractions, and cervical changes. There are eighteen referenced publications; most are recent (1990's).
The article is devoid of sonographic images, examples of which would have been instructional. There was little discussion of the endovaginal sonographic technique used other than to state, "With the maternal bladder empty, the cervical length was measured in the sagittal plane after visualizing simultaneously the internal and external cervical os." In addition there was no discussion of the experience of the observers, though it appears obvious that they were highly experienced; in less experienced hands the results may be more variable.
In the discussion one of the advantages of endovaginal sonography over digital examination it was stated: "Furthermore, accurate assessment of the effacement through the cervical canal may lead to local cervical activation of prostaglandins, which theoretically could increase the risk of preterm birth." There was no discussion of the same mechanism functioning due to "cervical massage" by the endovaginal transducer. For this reason an interesting follow-up research project would be to compare the accuracy of endovaginal against translabial and transperineal measurement of cervical length.5 While intuition would tell us there should be no difference in the measurements, to this reviewer's knowledge, this has not been scientifically tested except in the comparison of embryonic crown-rump lengths using transabdominal and endovaginal techniques.6, 7
Further commentary
This is a prospective observational study which addresses two important current questions about to the biophysical assessment of the cervix. The paper is topical and fits in well with recent studies which showed increased likelihood of preterm delivery with shortened cervical [1] and that shortening and/or funneling is associated with PTL [2]. It addresses two main questions:
1. which is the best test and 2. how does performance compare in singletons and twins.
1. The results show that in this study population, 30 mm cervical length is the cut-off for a significant improvement in prediction. Digital assessment in comparison is not predictive. Nor is funnelling: in addition to ROC curves, the authors are able to demonstrate through a multiple regression analysis of different parameters that funnelling has little to add once cervical length is in the equation. This is important new information and allows future management studies to concentrate on this measurement.
2. The comparison between singletons and twins is also novel and shows that twins need to be evaluated differently, most (61%) will go into PTL and that again cervical length only is useful, at the earlier gestational cut-off of 34 weeks.
My only quibbles are minor and relate to the way some of the data are presented: if clearly skewed - e.g. the digital assessment data in Table 2, or the gestational age & delay to delivery data in Table 3, non-paramteric methods would be more applicable and more informative - e.g. to state the number of pregnancies which continued for more than 2 weeks, four weeks, etc, (rather than a mean with a large standard deviation).
I think this is a good, authoritative paper which should help to formulate protocols for management trials in pregnancies presenting with threatened preterm labour. It is important to remember that this study makes a statement on the usefulness of these tests in a selected population, i.e. those who were admitted in threatened PTL and in whom contractions had settled (with or without tocolytics). Hence the results can NOT be transferred to other populations in whom cervical ultrasonography has been tried - e.g. in asymptomatic populations considered at high risk of preterm labor on history; those suspected of cervical incompetence; or as a screening test for the general population.
Terry J. DuBose, M.S., RDMS
Diagnostic Medical Sonography Correspondent OBGYN.net
Further commentary by Jason Gardosi MD, FRCS, MRCOG
OBGYN.net Advisory Board Member
Commentary Reference:
1. Benson CB & Doubilet PM: Sonographic Overview of Pregnancy, Chapter 13. In Berman MC & Cohen HL, Editors: Diagnostic Medical Sonography, A Guide to Clinical Practice: Obstetrics and Gynecology, 2nd Ed. J. B. Lippincott 1997; p. 235-236.
2. Parisi VM: Cervical Incompetence, Chapter 26. In Creasy RK & Resnick R, Editors: Maternal-Fetal Medicine: Principles and Practice, 2nd Ed. W.B. Saunders 1984; p. 447-451.
3. Hansmann M, Hackeloer B-J, Staudach A: Ultrasound Diagnosis in Obstetrics and Gynecology. Springer-Verlag, Berlin 1985; p. 345.
4. DuBose TJ: Fetal Sonography. W. B. Saunders 1996; p. 448-449
5. Mahony BS: Translabial and Transvaginal Ultrasound of the Cervix, Chapter 9. In Nyberg DA, Hill LM, Bohm-Velez M, et al: Transvaginal Ultrasound; Mosby Year Book 1992; p. 169-184.
6. Cullen MT, Green JJ, Reece EA & Hobbins JC: A Comparison of Transvaginal and Abdominal Ultrasound in Visualizing the First Trimester Conceptus. J Ultrasound Med, 8:565-569, 1989.
7. Goldstein SR & Wolfson R: Endovaginal Ultrasonic Measurement of Early Embryonic Size as a Means of Assessing Gestational Age. J Ultrasound Med, 13:27-31, 1994.
Further Commentery Reference:
1. Iams JD, Goldenberg RL, Meis PJ, etal. The length of the cervix and the risk of spontaneous delivery. N Eng J Med. 1996;334:567-572
2. Berghella V, Kuhlman K, Weiner S, et al. Cervical funneling: sonographic criteria predictive of preterm delivery. Ultrasound Obstet Gynecol 1997;10:161-166.
S1E4: Dr. Kristina Adams-Waldorf: Pandemics, pathogens and perseverance
July 16th 2020This episode of Pap Talk by Contemporary OB/GYN features an interview with Dr. Kristina Adams-Waldorf, Professor in the Department of Obstetrics and Gynecology and Adjunct Professor in Global Health at the University of Washington (UW) School of Medicine in Seattle.
Listen
Similar delivery times between misoprostol dosages among obese patients reported
May 29th 2024A recent study found that obese patients undergoing induction of labor experienced similar delivery times regardless of whether they received 50 μg or 25 μg of vaginal misoprostol, though multiparous patients showed faster delivery with the higher dosage.
Read More
Buprenorphine use in pregnancy linked to decreased fetal breathing movements
May 18th 2024According to a poster presented at ACOG 2024, use of the synthetic opioid buprenorphine depressed fetal breathing in biophysical profile assessments, but had no significant impact on other factors like amniotic fluid index or fetal tone.
Read More